Tabletop Turbidity Meter 'TL2300/2350'

Pursuing operability and high precision! A tabletop turbidity meter capable of measuring a wide range of turbidity from low to high turbidity.

The "TL2300/2350" is a tabletop turbidity meter designed to pursue operability and high precision. It irradiates the sample with light from a tungsten lamp, and the "TL2300" can measure up to 4000 NTU using a 90° scattered light detector, a transmitted light detector, and a forward scattered light detector. Additionally, the "TL2350" includes a backward scattered light detector, allowing measurements up to 10000 NTU. Measurement modes can be selected from three types: single, continuous, and RST (rapid settling sample). 【Features】 ■ Full-color touch screen ■ Self-diagnosis function ■ Calibration selection ■ Data storage and output ■ Built-in calibration compliant with the Japanese Pharmacopoeia *For more details, please refer to the PDF document or feel free to contact us.

  • Measurement and Analysis Equipment
  • Other analytical equipment
  • Analysis and prediction system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Tabletop Turbidity Meter 'TU5200'

Custom calibration feature supports PSL turbidity! A tabletop turbidity meter adopting a new 90° scattering method.

The "TU5200" is a tabletop turbidity meter capable of high-precision measurements even in low concentration areas. By placing a 10mL sample in a dedicated TU5 vial and setting it in the measurement section, the measurement will automatically start when the cover is closed. In single measurement mode, you can set an averaging time between 5 to 15 seconds, and in continuous measurement mode, you can set it between 5 to 90 seconds. 【Features】 ■ High sensitivity and high precision measurements in low turbidity areas ■ Custom calibration function ■ Compatible with PSL turbidity measurements ■ Signal accumulation averaging ■ External output *For more details, please refer to the PDF document or feel free to contact us.

  • Measurement and Analysis Equipment
  • Other analytical equipment
  • Analysis and prediction system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration